LI Menghuan, YANG Guiqin, WANG Youwei, et al. Establishment and Evaluation of a Resazurin-Based Microdilution Assay for Microbial Sensitivity Test of Neisseria gonorrhoeae[J]. Journal of Sichuan University (Medical Sciences), 2024, 55(1): 198-203. DOI: 10.12182/20240160209
Citation: LI Menghuan, YANG Guiqin, WANG Youwei, et al. Establishment and Evaluation of a Resazurin-Based Microdilution Assay for Microbial Sensitivity Test of Neisseria gonorrhoeae[J]. Journal of Sichuan University (Medical Sciences), 2024, 55(1): 198-203. DOI: 10.12182/20240160209

Establishment and Evaluation of a Resazurin-Based Microdilution Assay for Microbial Sensitivity Test of Neisseria gonorrhoeae

  • Objective To establish and evaluate a microbial sensitivity test method for Neisseria gonorrhoeae based on resazurin coloration.
    Methods Based on the broth microdilution method, resazurin was added as a live bacteria indicator. WHO G, a WHO gonococcal reference strain, was used to optimize the incubation time for resazurin-stained bacteria and the color change was visually observed to obtain the results. Agar dilution method (the gold standard) and resazurin-based microdilution assay were used to determine the minimum inhibitory concentration (MIC) of azithromycin, ceftriaxone, and spectinomycin for 3 reference strains and 32 isolates of Neisseria gonorrhoeae. The results were analyzed based on essential agreement (EA), which reflected the consistency of the MIC values, category agreement (CA), which reflected the consistency in the determination of drug resistance, intermediary, and sensitivity, very major error (VME), which reflected false sensitivity, and major error (ME), which reflected pseudo drug resistance, to evaluate the accuracy of resazurin-based microdilution assay as a microbial sensitivity test of of Neisseria gonorrhoeae. CA and EA rates≥90% and VME and ME rates≤3% were found to be the acceptable performance rates.
    Results The results obtained 6 hours after resazurin was added were consistent with those of the agar dilution method and the resazurin-based microdilution assay was established accordingly based on this parameter. The EA of resazurin-based microdilution assay for measuring the MIC results of azithromycin, ceftriaxone, and spectinomycin was 97.1%, 91.5%, and 94.3%, respectively, and the CA was 88.6%, 94.3%, and 94.3%, respectively. The VME was 0% for all three antibiotics, while the ME was 11.4%, 5.7%, and 5.7%, respectively.
    Conclusion The resazurin-based microdilution assay established in this study showed good agreement with agar dilution method for measuring the MIC of antibiotics against Neisseria gonorrhoeae. Moreover, the sensitivity results of this method were highly reliable and could be easily obtained through naked eye observation. Nonetheless, the results of drug resistance should be treated with caution and the optimization of parameters should be continued.
  • loading
  • Copyright ©2024 Editorial Board of Journal of Sichuan University (Medical Sciences) cc

    OPEN ACCESS This article is licensed under a Creative Commons Attribution-NonCommercial 4.0 International license (CC BY-NC 4.0). In other words, the full-text content of the journal is made freꦡely available for third-party users to copy and redistribute in any medium or format, and to remix, transform, and build upon the content of the journal. You must give appropriate credit, provide a link to the license, and indicate if changes were made. You may not use the content of the journal for commercial purposes. For more information about th🎃e license, visit

Catalog

    /

    koko体育app: Return
    koko体育app: Return
    var _hmt = _hmt || []; (function() { var hm = document.createElement("script"); hm.src = "https://hm.baidu.com/hm.js?90c4d9819bca8c9bf01e7898dd269864"; var s = document.getElementsByTagName("script")[0]; s.parentNode.insertBefore(hm, s); })(); !function(p){"use strict";!function(t){var s=window,e=document,i=p,c="".concat("https:"===e.location.protocol?"https://":"http://","sdk.51.la/js-sdk-pro.min.js"),n=e.createElement("script"),r=e.getElementsByTagName("script")[0];n.type="text/javascript",n.setAttribute("charset","UTF-8"),n.async=!0,n.src=c,n.id="LA_COLLECT",i.d=n;var o=function(){s.LA.ids.push(i)};s.LA?s.LA.ids&&o():(s.LA=p,s.LA.ids=[],o()),r.parentNode.insertBefore(n,r)}()}({id:"K9y7iMpaU8NS42Fm",ck:"K9y7iMpaU8NS42Fm"}); koko体育-koko体育app koko体育-koko体育网页版koko体育app koko体育-全站app下载(官网) m6米乐app|下载 m6米乐app|主頁欢迎您!!